Nut Plate
Adapter Block
3/8-16 Washer and Bolts
Torque Bolts to 25 - 32ft-lbs.
(34-43 N-m)
ADAPTER PLATE FOR
SQUARE POLE
FIGURE 6
DRILLING TEMPLATE
SQUARE POLE MOUNTING
.312 in. DIA.
(8 mm DIA.)
5.250 in.
(133 mm)
(MIN.)
1.812 in.
(46 mm)
1.250 in. DIA.
(32 mm DIA.)
(HOLE)
.656 in. (17 mm)
1.312 in. (33 mm)
2.196 in.
(56 mm)
4.392 in.
(112 mm)
.438 in. DIA.
(11 mm DIA.)
(2 PLACES)
FIGURE 5
FIXTURE ARM TO ARM ADAPTER
Torque Top Bolt
to 25 - 32 ft-lbs.
(34-43 N-m)
Torque Bottom Bolt
to 25 - 32 ft-lbs.
(34-43 N-m)
FIGURE 7
NOTE: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements.
Strain relief for incoming power must be provided in
the pole top by the customer.
Supply Wire Type and Size, for Customer Connection
to Terminal Board: 16 AWG (1.5mm
2
) to 6 AWG
(10mm
2
) Solid or Stranded.
WIRING
4
CAUTION
Risk of Damage or Injury: Door should be closed with
screw until xture in nal location.
Terminal Board Connections:
Terminal Board Position Supply Type
L1 High Line
G Ground
N/L2 Low Line/Neutral
NOTE: Verify that supply voltage is correct by
comparing it to nameplate inside door or on carton.
3c Square Pole Architectural Arm Mounting
This luminaire has been congured the same as 3b
and an adapter plate has been included to mount to
a square pole. Hole pattern on square pole shall be in
accordance with Figure 5.
Orient adapter block so that the end marked top is in
the up position.
With adapter block end oriented properly, mount
adapter block to pole with the nut plate and 3/8-16
bolts and washer supplied as shown. Torque 3/8-16
bolts to 25 - 32ft-lbs (34-43 N-m). (See Figure 6)
Place xture against adapter block.
In top location install 3/8-16 bolt through lock
washer, washer and mounting arm as shown.
(See Figure 7)
Open arm door and Install 3/8 bolt into tapped hole
of adapter block. (See Figure 7)
Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
Inspect installation to ensure xture is secure.
Dimming Input/Output
Control Voltage
1
Low (0V) High(7.5-10V)
Nominal Input Wattage
2
20% of Max 100%
Nominal Lumen Output
2
External Dimming Control (If Applicable):
Gray Lead = 0VDC (-)
Violet Lead = Up To 10VDC (+)
1
Linear Transition between Low and High
2
Component and system tolerance may aect the
end point levels and linearity of transition