GE AZ65H07DAC Manual de instalación

Busca en linea o descarga Manual de instalación para No GE AZ65H07DAC. GE AZ65H07DAC Installation Instructions Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
49-7756 02-16 GE
Air Conditioners
AZ45
AZ65
Owner’s Manual and
Installation Instructions
Write the model and serial
numbers here:
Model # ___________________
Serial # ____________________
Find these numbers on a label
behind the room cover on the
base pan.
Zoneline
®
Safety Instructions ...........2-4
Operating Instructions
Controls ...........................5
Air Direction. . . . . . . . . . . . . . . . . . . . . . . . 6
To Remove the Room Cover ........6
Ventilation Control .................6
Auxiliary Controls ...............7-11
Remote Thermostat ...............11
Care and Cleaning
Base Pan .........................12
Outdoor Coils .....................12
Room Cover and Case .............12
Ventilation Filter ...................12
Air Filters .........................13
Installation Instructions
Preparation .......................14
Replacing an Existing Unit .........15
Electrical Connection ...........16-18
Installing the Zoneline .........19, 20
Optional Drain Kit .................21
Troubleshooting Tips .....22, 23
Normal Operating Sounds .........24
Consumer Support
Ownership Registration ........25, 26
Warranty .........................27
Consumer Support ........Back Cover
Español
For a Spanish version of this
manual, visit our Website at
www.zoneline.com.
Para consultar una version
en español de este manual
de instrucciones, visite nuestro
sitio de internet
www.zoneline.com.
Français
For a French version of this
manual, visit our Website at
www.zoneline.com.
Pour un version français de
ce manuel d’utilisation, veuillez
visiter notre site web à l’adresse
www.zoneline.com.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Air Conditioners

49-7756 02-16 GEAir ConditionersAZ45AZ65Owner’s Manual and Installation InstructionsWrite the model and serial numbers here:Model # ______________

Pagina 2 - SAVE THESE INSTRUCTIONS

Auxiliary controls on your Zoneline$X[LOLDU\&RQWUROV³7HUPLQDO&RQQHFWLRQVThe auxiliary control terminal connects are located behind the room

Pagina 3 - CONSERVEZ CES INSTRUCTIONS

External Fan (Field Installed)When connected, an auxiliary or external fan can be controlled with the indoor fan motor on the Zoneline. Connections pr

Pagina 4 - GUARDE ESTAS INSTRUCCIONES

Operating InstructionsBase PanIn some installations, dirt or other debris may be blown into the unit from the outside and settle in the base pan (the

Pagina 5 - Controls

To maintain optimum performance, clean the filters at least every 30 days.Air FiltersFRONTFRONT'LUW\ILOWHU³1HHGVFOHDQLQJ &ORJJHGILOWHU³*U

Pagina 6 - To Remove the Room Front

BEFORE YOU BEGINInstallation Instructions Zoneline Air ConditionersRead these instructions completely and carefully.• IMPORTANT – Save these instru

Pagina 7 - 6PDUW)DQ³&RROLQJ+HDWLQJ

Installation Instructions Use the correct wall caseThis unit is designed to be installed in a GE plastic or insulated metal wall case. This minimizes

Pagina 8

Installation Instructions ELECTRICAL SUBBASE CONNECTION Power cords may include an arc fault interruption or a leakage current detection interrupt

Pagina 9

Installation Instructions 265 VOLT ELECTRICAL CONNECTION OPTIONS Connection of this 265 V AC product to a branch circuit MUST be done by direct con

Pagina 10

Installation Instructions POWER CONNECTION CHARTPower Cord ConnectionsDirect Connections230/208 Volt Power Supply Kitswith Current LeakageDetection De

Pagina 11 - IMPORTANT:

Installation Instructions 1. INSTALL THE WALL CASE AND EXTERIOR GRILLE The RAB71A/B series or RAB77A4/77B wall case must be properly inst

Pagina 12 - Care and cleaning

2IMPORTANT SAFETY INFORMATIONREAD ALL INSTRUCTIONS BEFORE USINGFor your safety, the information in this manual must be followed to minimize the risk o

Pagina 13

Installation Instructions INSTALLING THE ZONELINE (cont.) 3. INSTALL THE UNIT INTO THE WALL CASE Slide the unit into the wall case and secu

Pagina 14 - IMPORTANT ELECTRICAL

Installation Instructions 237,21$/³'5$,1.,7,167$//$7,21Dry Air 25 Series models are designed to improve dehumidification by 25%. Since more moi

Pagina 15 - REPLACING AN EXISTING UNIT

Before you call for serviceTroubleshooting Tips Save time and money! Review the charts on the following pages first and you may not need to call for

Pagina 16 - Power supply kit

Problem Possible Causes What To DoThe air is not always The heat pump is not • This is normal. The heat pump will produce warm air cool or hot du

Pagina 17 - AVERTISSEMENT

Normal Operating SoundsYou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidit

Pagina 18 - POWER CONNECTION CHART

25Product RegistrationComplete and mail your Consumer Production Registration today. Have the peace of mind of knowing we can contact you in the unli

Pagina 19

Please place in envelope and mail to:Please place in envelope and mail to:Veuillez mettre dans une enveloppe et envoyez à :26Product Registration

Pagina 20

Zoneline Warranty Service trips to your site to teach you how to use the product. Improper installation, delivery or maintenance. If you have a

Pagina 21

Printed in USAConsumer Support GE Appliances Website GEAppliances.comHave a question or need assistance with your appliance? Try the GE Appliances We

Pagina 22 - Before you call for service

CONSIGNES DE SÉCURITÉ IMPORTANTESLISEZ TOUTES LES INSTRUCTIONS AVANT L’UTILISATIONPour votre sécurité, veuillez observer les consignes de ce manuel af

Pagina 23

INFORMACIÓN IMPORTANTE DE SEGURIDADLEA TODAS LAS INSTRUCCIONES ANTES DE USARPara su seguridad, se debe seguir la información de este manual para minim

Pagina 24 - Things that are normal

About Your Heat Pump (AZ65 only)Heat pumps can save money by removing heat from the outside DLU³HYHQZKHQWKHRXWVLGHWHPSHUDWXUHLVEHORZIUHH]LQJ³DQ

Pagina 25 - Product Registration

Ventilation Control*NOTE: Two shipping screws must be removed from the vent door before use. See the Installation Instructions in the back of this man

Pagina 26

Auxiliary controls on your Zoneline $X[LOLDU\&RQWUROV³$X[6HW%XWWRQWhile the unit is preset to what most customers prefer, the auxiliary control

Pagina 27 - Zoneline Warranty

8Auxiliary controls on your ZonelineConstant ON FanPress MODE until a 4 appears in the first digit of the display to set the fan to run continuously a

Pagina 28 - Printed in USA

Auxiliary controls on your Zoneline Duct ModeThis setting is used when the unit is installed with a duct adapter kit. If the unit is ducted, the Duct