1GE Industrial SystemsAV - 30 0iAV - 30 0iQuick Start Up GuideTM

Pagina 2

103.1 Maximum cable cross section for regulator terminalsMaximum Permissible Cable Cross-Section Tightening[mm2]torqueflexible multi-core [Nm]1...79 0

Pagina 3 - Table of Contents

115. Encoder terminals (XE connector)Designation Function I/O max.voltage max.currentChannel B - 5V digital or 10 mA digitalorFor B- digital or B-CO

Pagina 4

125.2 JUMPERS settingEncoder/Jumpers setting S11 S12 S13 S14 S15 S16 S17 S18 S19 S20 S21 S22 S23DE OFF OFF OFF OFF OFF OFF ON(*)------SE ON ON ON ON O

Pagina 5

13List of dip-switch S3Hp 3/4 1 2 3 5 7.5 10 15 20S1ON OFF ON OFF OFF ON OFF ON OFFS2OFF ON ON OFF OFF OFF ON ON OFFS3OFF OFF OF

Pagina 6

146. Keypad operationThe keypad is made of a LCD display with two 16-digit lines, seven LEDs and nine function keys.Keypad LED ModuleShiftJogHelpAlarm

Pagina 7 - Functional connection diagram

15Keypad buttonsJogHelpAlarmEscapeHomeEnterShiftText reference[START][STOP][Increase] / [Jog][Decrease] / [Rotation control][Down arrow] / [Help][Up a

Pagina 8 - 2. Overview

16Moving inside a menu

Pagina 9 - 3. Control Terminals

177. Pre Power ChecksThe following should be checked before switching ON the Drive:Grounds / Grounding• Verify ground connections between the drive an

Pagina 10 - 4. power terminals

188. Quick tuning1. After a complete check of wiring, turn the power on:• The following voltages must be present:Terminal 7, +10V to terminal 9 (on r

Pagina 11 - • •••••••••••••

19of this is trying to [Enter] a value for “Nominal Currentthat is less than 30% of the drive rating. This is notallowed due to problems encountered

Pagina 12

2This book is referred to SW version 1.X00This book replaces the Instruction Book Rev. 1.0c (09/98)These instructions do not purport to cover all deta

Pagina 13 - List of dip-switch S3

20NOTE:“xxx range error” or “timeout” messages may also occur insome extreme parameter ranges. Repeat the tune in thiscase. If error messages are pers

Pagina 14 - 6. Keypad operation

21Control buttonsJogShift SequencingPress START button to command the Drive to the Enable andRun statePress STOP button commands to stop the Drive fr

Pagina 15

229. OptionsEncoder verification: Set the Drive in V/f mode and runthe motor, enable and start the drive and set an analogreference. If the reference

Pagina 16 - Moving inside a menu

2311. TroubleshootingOverflow listCODE CAUSES10 ; 54 The ratio between the Encoder 1 pulses[416] and the number of motor pole pairs must behigher than

Pagina 17 - 7. Pre Power Checks

24List of Self-tuning Error MessagesGeneric messagesDescription Note“Drive disabled”: Provide enable input by setting terminal 12 high.“Not ready”: “T

Pagina 18 - 8. Quick tuning

25Failure alarms in the keypad displayFailure alarm Possible causesBU overload The braking duty cycle is out of the allowed rangeBus loss Failure in t

Pagina 19

26Interrupt error An unused interrupt has occurredSwitch off the drive and restartIf still unsuccessful, the fault is probably internal. Contact your

Pagina 20

27Undervoltage Line voltage parameter incorrectly set. Remedy: set parameter correctly and then acknowledgethe failure via RESET*.The incoming voltage

Pagina 21

28Motor accelerates immediately to maximum speedReference set via analog input: Check whether the signal varies from min. to max.Potentiometer used fo

Pagina 22 - 9. Options

29The speed during acceleration with maximum current is not linearReduce the Speed I and Speed P proportionally. If this does not lead to an improveme

Pagina 23 - Overflow list

3Table of Contents1. Safety Precautions - Precautions de securité ...

Pagina 24

GEK-105661 (5M 5/99)GE Industrial Systems1501 Roanoke Boulevard, Suite 435Salem, VA 241531-800-543-6196www.GEindustrial.com

Pagina 25

41. Safety Precautions - Precautions de securitéWARNING/ATTENTION!According to the EEC standards the AV300i should be usedonly after checking that the

Pagina 26

5CAUTION / PRECAUTION:Do not operate the drive without a ground wire beingconnected. The motor chassis should be grounded toearth through a ground le

Pagina 27 - Other faults

66. A capacitative load (e.g. variable power factor capacitors) shouldnot be connected to the output of the drive (terminals U2, V2, W2).Aucune charge

Pagina 28

7Functional connection diagramACPowerSupplyCabinetMounting panelACDriveACLineReactorGroundBusMotorcableterminalsAC MotorEncoder cableEMI filterU1V1W1U

Pagina 29

8Underline: When words are underlined, they refer to akey on the keypad.Quotes: Quote marks are put around words which will beseen in the display wi

Pagina 30 - 1-800-543-6196

93. Control Terminals12345678912131415161819BU-External brakingunit (optional)Strip X1FunctionmaxProgrammable / configurable analog differential input

Comentarios a estos manuales

Sin comentarios