NODE Command
The NODE command has the form:
NODE
This command causes the TCP/IP Ethernet Interface sign-on message to be printed out
on the screen. When the TCP/IP Ethernet Interface is executing the Soft Switch Entry
Utility, the reason that the utility was entered is also displayed.
A typical NODE command is shown below:
> node
IC697 PLC Factory LAN Interface
Copyright (c) 1990-1995. All rights reserved.
PROM version 2.00 (xxAx), Software version 2.00 (xxAx)
TCP/IP Ethernet
IP address = 3.16.18.47
MAC address = <<080019010177>> MAC default = <<080019010177>>
EM7A2
OK Command
This command causes the STATUS OK LED to turn ON. It has no effect on the contents
of the exception log.
The OK command has the form:
OK
A typical OK command is shown below:
= ok
Display modified
PING Command
The PING command has the form:
PING <node> [ <cnt> [ <sch> [ <len> ] ] ]
where <node> is the Internet address of the destination.
<cnt> is the number of ICMP echo requests to send to the destination.
<sch> is the number of 10 millisecond intervals to wait for a reply from the
destination, and send the next ICMP echo.
<len> is the length of the ICMP echo message (minimum of 8 bytes).