Dimensions and Installation Information
Listed by
Underwriters
Laboratories
PP989SN
GE Profile
Series 30" Downdraft Electric Cooktop
For answers to your Monogram
®
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
service, 800.626.2000.
Specification Revised 3/13
220978
Wall Installation: Wall installations
require 25” countertop
depth. When
cabinet is flush against the wall, the
fan housing can be rotated to the
horizontal position for direct
venting
through rear wall. Make a countertop
cutout in the range
cabinet according to unit dimensions and installation type.
Duct hole is positioned in back of cabinet for through-the-
wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a
minimum 26
countertop
depth is suggested. Blower should
be in vertical position. Island or peninsula cabinets may
require adjustment in cutout depth and/or location within
the width dimensions. Duct hole is positioned in bottom of
cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and
rear wall ducting, 6” PVC duct or locally approved piping
should be used if installing under a poured concrete slab.
Receptacle Location: Install an approved junction box
within shaded area shown in diagram. Junction box must
be at least 10-1/2" below top of cabinet.
Installation Information: Before installing, consult installation
instructions, packed with product, for current dimensional
data. Note: Electrical cable is not supplied with unit.
These cooktops are approved for indoor use only.
KW Rating
240V
9.1
208V
6.9
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*UL Requirement.
Note: A 6" minimum spacing to adjacent side wall is required
20
9
4
10-1/2
16
C
L
Cabinet Dimensions (in inches)
*Note: A 6" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
22
7
16ʺ
(22
9
16ʺ SS)
20
1
2ʺ
22ʺ
29
7
8ʺ
(30ʺ SS)
2
3
16ʺ
(2
1
4ʺ SS)
28
3
4ʺ
Vista de pagina 0
1 2 3

Indice de contenidos

Pagina 1 - PP989SN

Dimensions and Installation InformationListed by Underwriters LaboratoriesPP989SN GE Profile™ Series 30" Downdraft Electric Cooktop For answers t

Pagina 2

Dimensions and Installation Information Dimension and installation information are shown in inches.Listed by Underwriters LaboratoriesPP989SN GE Profi

Pagina 3

PP989SN GE Profile™ Series 30" Downdraft Electric Cooktop Specification Revised 3/13220978Features and Benefits• Downdraft Exhaust - Powerful e

Comentarios a estos manuales

Sin comentarios